{"id":7274,"date":"2026-03-04T09:28:27","date_gmt":"2026-03-04T02:28:27","guid":{"rendered":"https:\/\/vintec.com.vn\/?page_id=7274"},"modified":"2026-03-09T11:40:41","modified_gmt":"2026-03-09T04:40:41","slug":"solution-water-wastewater","status":"publish","type":"page","link":"https:\/\/vintec.com.vn\/vi\/solution-water-wastewater\/","title":{"rendered":"Solution Water &#038; Wastewater"},"content":{"rendered":"<div class=\"row\"  id=\"row-2119860452\">\n\n\t<div id=\"col-1514518747\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h4><span style=\"color: #ff0000;\"><strong>Solution Water &amp; Wastewater<\/strong><\/span><\/h4>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\">Vintec \u0111\u00e3 v\u00e0 \u0111ang cung c\u1ea5p thi\u1ebft b\u1ecb \u0111o qu\u00e1 tr\u00ecnh hi\u1ec7n \u0111\u1ea1i \u0111\u1ec3 gi\u00fap h\u1ec7 th\u1ed1ng cung c\u1ea5p n\u01b0\u1edbc s\u1ea1ch \u1ed5n \u0111\u1ecbnh, x\u1eed l\u00fd n\u01b0\u1edbc th\u1ea3i b\u1ea3o v\u1ec7 m\u00f4i tr\u01b0\u1eddng n\u01b0\u1edbc, qu\u1ea3n l\u00fd th\u1ea5t tho\u00e1t n\u01b0\u1edbc v\u00e0 t\u1ed1i \u01b0u h\u00f3a v\u1eadn h\u00e0nh nh\u00e0 m\u00e1y \u0111\u1ec3 gi\u1ea3m chi ph\u00ed v\u1eadn h\u00e0nh.<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-7275 size-full\" src=\"https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/WWW.jpg\" alt=\"\" width=\"1091\" height=\"636\" srcset=\"https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/WWW.jpg 1091w, https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/WWW-768x448.jpg 768w, https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/WWW-18x10.jpg 18w\" sizes=\"auto, (max-width: 1091px) 100vw, 1091px\" \/><\/p>\n<h5><span style=\"color: #ff0000;\"><strong>\u1ee8ng d\u1ee5ng<\/strong><\/span><\/h5>\n<ul>\n<li>Wastewater Treatment Plants<\/li>\n<li>Regeneration of Water Wells<\/li>\n<li>Water Abstraction Control<\/li>\n<li>Water Distribution Networks<\/li>\n<li>Drinking Water<\/li>\n<li>Pressure Filter System in Water Treatment Plants<\/li>\n<li>Booster Pump Works with Collector Well in Water Treatment Facilities<\/li>\n<li>Corrosion Protection and Disinfection<\/li>\n<li>Clean Water From Water Treatment Facilities<\/li>\n<li>Open Channel Measurement in Partially Filled Wastewater and Sludge Purification Plants<\/li>\n<li>Open Channel Measurement in Partially Filled Water Distribution Channels<\/li>\n<li>Untreated Wastewater<\/li>\n<li>Measurement of Iron Chloride in Light Load Aeration<\/li>\n<li>Flow Measurement of Sludge<\/li>\n<li>Methanol Measurement with Coriolis Flowmeters<\/li>\n<li>Aeration Process<\/li>\n<li>Biogas Measurement<\/li>\n<li>Biogas for Cogeneration Plants in Wastewater Facilities<\/li>\n<li>Biogas from Landfills for Cogeneration<\/li>\n<\/ul>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-522422129\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h5><strong style=\"font-size: 14.4px;\"><a href=\"https:\/\/smartmeasurement.com\/magnetic-flow-meters\/\"><span style=\"color: #ff0000;\">Magnetic flowmeters<\/span><\/a><\/strong><\/h5>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\">ALMAG Series<\/span><\/p>\n<p><a href=\"https:\/\/smartmeasurement.com\/magnetic-flow-meters\/\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-7292\" src=\"https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/ALMAG_Flowmeter_Matrix.jpg\" alt=\"\" width=\"311\" height=\"304\" srcset=\"https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/ALMAG_Flowmeter_Matrix.jpg 225w, https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/ALMAG_Flowmeter_Matrix-12x12.jpg 12w\" sizes=\"auto, (max-width: 311px) 100vw, 311px\" \/><\/a><\/p>\n<ul>\n<li><a href=\"https:\/\/smartmeasurement.com\/\"><strong>Smart Measurement\u2019s<\/strong><\/a> offers a complete line of magnetic flow meters suitable for use in the water and wastewater industries. From ALMAG-WP for general-purpose applications; No power or only solar power are available, the battery powered ALMAG-BAT is available; For large pipe sizes, the insertion style ALMAG-IS can accommodate pipe sizes of up to 120\u201d (3000 mm); ALMAG-EG which is frequently used for BTU\/energy flow measurement required in building automation application<\/li>\n<\/ul>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1525376395\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h5 class=\"bdr-deco\"><strong><a href=\"https:\/\/smartmeasurement.com\/turbine-flow-meters\/\"><span style=\"color: #ff0000;\">Turbine flowmeters<\/span><\/a><\/strong><\/h5>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\">ALTM Series<\/span><\/p>\n<p><a href=\"https:\/\/smartmeasurement.com\/turbine-flow-meters\/\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-7293\" src=\"https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/ALTM-T-series-TURBINE.jpg\" alt=\"\" width=\"297\" height=\"296\" srcset=\"https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/ALTM-T-series-TURBINE.jpg 425w, https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/ALTM-T-series-TURBINE-12x12.jpg 12w\" sizes=\"auto, (max-width: 297px) 100vw, 297px\" \/><\/a><\/p>\n<ul>\n<li><a href=\"https:\/\/smartmeasurement.com\/\"><strong>Smart Measurement\u2019s<\/strong><\/a>\u00a0ALTM turbine flow meter comes in sizes ranging from \u00bd\u201d to 12\u201d (15-300 mm) and features a wide turn-down ratio with minimum uncertainty and a very repeatable output.\u00a0 The ALTM is excellent for precise measurement of instantaneous flows of low-viscosity fluids such as tap and demineralized water, fuels, liquefied gasses, light fuel oils, solvents, and pharmaceutical fluids.<\/li>\n<\/ul>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-2077184522\">\n\n\t<div id=\"col-1042195218\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h5>\u00a0<strong style=\"font-size: 14.4px;\"><a href=\"https:\/\/smartmeasurement.com\/ultrasonic-flow-meters\/\"><span style=\"color: #ff0000;\">\u0110\u1ed3ng h\u1ed3 \u0111o l\u01b0u l\u01b0\u1ee3ng n\u01b0\u1edbc ki\u1ec3u si\u00eau \u00e2m<\/span><\/a><\/strong><\/h5>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\">ALSONIC Series<\/span><\/p>\n<p><a href=\"https:\/\/smartmeasurement.com\/ultrasonic-flow-meters\/\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-6695\" src=\"https:\/\/vintec.com.vn\/wp-content\/uploads\/2024\/10\/ultrasonic-flowmeters-1.jpg\" alt=\"\" width=\"490\" height=\"273\" srcset=\"https:\/\/vintec.com.vn\/wp-content\/uploads\/2024\/10\/ultrasonic-flowmeters-1.jpg 406w, https:\/\/vintec.com.vn\/wp-content\/uploads\/2024\/10\/ultrasonic-flowmeters-1-18x10.jpg 18w\" sizes=\"auto, (max-width: 490px) 100vw, 490px\" \/><\/a><\/p>\n<ul>\n<li>D\u1ea3i s\u1ea3n ph\u1ea9m ALSONIC s\u1eed d\u1ee5ng nguy\u00ean l\u00fd \u0111o l\u01b0u l\u01b0\u1ee3ng si\u00eau \u00e2m Doppler v\u00e0  transit-time cho ph\u00e9p l\u1eafp \u0111\u1eb7t k\u1eb9p ngo\u00e0i kh\u00f4ng ti\u1ebfp x\u00fac (clamp-on) v\u00e0 l\u1eafp \u0111\u1eb7t tr\u1ef1c ti\u1ebfp trong c\u00e1c \u1ee9ng d\u1ee5ng \u0111o l\u01b0u l\u01b0\u1ee3ng ch\u1ea5t l\u1ecfng. Gi\u00fap t\u1ed1i \u01b0u chi ph\u00ed l\u1eafp \u0111\u1eb7t v\u00e0 n\u00e2ng cao \u0111\u1ed9 tin c\u1eady trong v\u1eadn h\u00e0nh.<\/li>\n<\/ul>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-256882469\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h5 class=\"bdr-deco\"><strong><a href=\"https:\/\/smartmeasurement.com\/open-channel-flow-meters\/\"><span style=\"color: #ff0000;\">\u0110\u1ed3ng h\u1ed3 \u0111o l\u01b0u l\u01b0\u1ee3ng k\u00eanh h\u1edf<\/span><\/a><\/strong><\/h5>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\">ALSONIC Series<\/span><\/p>\n<p><a href=\"https:\/\/smartmeasurement.com\/open-channel-flow-meters\/\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-6692\" src=\"https:\/\/vintec.com.vn\/wp-content\/uploads\/2024\/10\/open-channel.jpg\" alt=\"\" width=\"520\" height=\"285\" srcset=\"https:\/\/vintec.com.vn\/wp-content\/uploads\/2024\/10\/open-channel.jpg 659w, https:\/\/vintec.com.vn\/wp-content\/uploads\/2024\/10\/open-channel-18x10.jpg 18w\" sizes=\"auto, (max-width: 520px) 100vw, 520px\" \/><\/a><\/p>\n<ul>\n<li>\u0110o l\u01b0u l\u01b0\u1ee3ng ch\u00ednh x\u00e1c trong c\u00e1c k\u00eanh h\u1edf, \u0111\u00f3ng vai tr\u00f2 quan tr\u1ecdng \u0111\u1ed1i v\u1edbi vi\u1ec7c qu\u1ea3n l\u00fd gi\u00e1m s\u00e1t trong h\u1ec7 th\u1ed1ng x\u1eed l\u00fd n\u01b0\u1edbc th\u1ea3i (k\u00eanh, \u1ed1ng d\u1eabn,...), gi\u00e1m s\u00e1t n\u01b0\u1edbc m\u01b0a v\u00e0 h\u1ec7 th\u1ed1ng k\u00eanh m\u01b0\u01a1ng t\u01b0\u1edbi ti\u00eau.<\/li>\n<\/ul>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-1511783899\">\n\n\t<div id=\"col-1596251995\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h5 class=\"bdr-deco\"><strong><a href=\"https:\/\/smartmeasurement.com\/ultrasonic-flow-meters\/portable-clamp-on\/\"><span style=\"color: #ff0000;\">\u0110\u1ed3ng h\u1ed3 \u0111o l\u01b0u l\u01b0\u1ee3ng si\u00eau \u00e2m c\u1ea7m tay<\/span><\/a><\/strong><\/h5>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\">ALSONIC Series<\/span><\/p>\n<p><a href=\"https:\/\/smartmeasurement.com\/ultrasonic-flow-meters\/portable-clamp-on\/\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-6702\" src=\"https:\/\/vintec.com.vn\/wp-content\/uploads\/2024\/10\/portable-clamp-on-ultrasonic-transit-time-flowmeters.jpg\" alt=\"\" width=\"392\" height=\"245\" srcset=\"https:\/\/vintec.com.vn\/wp-content\/uploads\/2024\/10\/portable-clamp-on-ultrasonic-transit-time-flowmeters.jpg 352w, https:\/\/vintec.com.vn\/wp-content\/uploads\/2024\/10\/portable-clamp-on-ultrasonic-transit-time-flowmeters-18x12.jpg 18w\" sizes=\"auto, (max-width: 392px) 100vw, 392px\" \/><\/a><\/p>\n<ul>\n<li>\u0110\u1ed3ng h\u1ed3 \u0111o l\u01b0u l\u01b0\u1ee3ng si\u00eau \u00e2m c\u1ea7m tay (Portable) d\u01b0\u1ee3c s\u1eed d\u1ee5ng r\u1ed9ng r\u00e3i cho c\u00e1c \u1ee9ng d\u1ee5ng c\u1ea7n ch\u1ea9n \u0111o\u00e1n, \u0111o l\u01b0u l\u01b0\u1ee3ng nhanh t\u1ea1i hi\u1ec7n tr\u01b0\u1eddng. T\u00ednh di \u0111\u1ed9ng k\u1ebft h\u1ee3p v\u1edbi kh\u1ea3 n\u0103ng \u0111o v\u00e0 l\u01b0u tr\u1eef d\u1eef li\u1ec7u l\u01b0u l\u01b0\u1ee3ng th\u00f4ng minh, cho ph\u00e9p \u0111\u00e1nh gi\u00e1 to\u00e0n di\u1ec7n v\u00e0 kh\u1eafc ph\u1ee5c s\u1ef1 c\u1ed1 trong c\u00e1c t\u00ecnh hu\u1ed1ng li\u00ean quan \u0111\u1ebfn c\u00e1c \u1ee9ng d\u1ee5ng m\u00f4i ch\u1ea5t ch\u1ea5t l\u1ecfng \u0111\u1ea7y th\u00e1ch th\u1ee9c.<\/li>\n<\/ul>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1847518150\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h5 class=\"bdr-deco\"><strong><a href=\"https:\/\/smartmeasurement.com\/energy-flow-meters\/\"><span style=\"color: #ff0000;\">\u0110\u1ed3ng h\u1ed3 \u0111o n\u0103ng l\u01b0\u1ee3ng nhi\u1ec7t (BTU)<\/span><\/a><\/strong><\/h5>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\">ALSONIC Series<\/span><\/p>\n<p><a href=\"https:\/\/smartmeasurement.com\/energy-flow-meters\/\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-6705\" src=\"https:\/\/vintec.com.vn\/wp-content\/uploads\/2024\/10\/water_and_energy_ultrasonic_flow_meters.jpg\" alt=\"\" width=\"459\" height=\"258\" srcset=\"https:\/\/vintec.com.vn\/wp-content\/uploads\/2024\/10\/water_and_energy_ultrasonic_flow_meters.jpg 391w, https:\/\/vintec.com.vn\/wp-content\/uploads\/2024\/10\/water_and_energy_ultrasonic_flow_meters-18x10.jpg 18w\" sizes=\"auto, (max-width: 459px) 100vw, 459px\" \/><\/a><\/p>\n<ul>\n<li>Khi c\u00e1c gi\u1ea3i ph\u00e1p \u0111o l\u01b0u l\u01b0\u1ee3ng si\u00eau \u00e2m tr\u1edf n\u00ean ph\u1ed5 bi\u1ebfn, ti\u1ebft ki\u1ec7m chi ph\u00ed h\u01a1n, thay th\u1ebf cho c\u00e1c \u0111\u1ed3ng h\u1ed3 n\u01b0\u1edbc c\u01a1 truy\u1ec1n th\u1ed1ng, mang l\u1ea1i hi\u1ec7u qu\u1ea3 v\u01b0\u1ee3t tr\u1ed9i v\u00e0 kh\u00f4ng y\u00eau c\u1ea7u b\u1ea3o tr\u00ec. D\u1ea3i s\u1ea3n ph\u1ea9m \u0111\u1ed3ng h\u1ed3 \u0111o n\u0103ng l\u01b0\u1ee3ng nhi\u1ec7t BTU chuy\u00ean d\u00f9ng cho ki\u1ec3m so\u00e1t l\u01b0u l\u01b0\u1ee3ng n\u01b0\u1edbc c\u1ea5p \u0111\u1ebfn c\u00e1c khu \u0111\u00f4 th\u1ecb\/ d\u00e2n d\u1ee5ng c\u0169ng nh\u01b0 \u1ee9ng d\u1ee5ng ki\u1ec3m so\u00e1t nhi\u1ec7t l\u01b0\u1ee3ng s\u1eed d\u1ee5ng trong \u1ee9ng d\u1ee5ng t\u1ef1 \u0111\u1ed9ng h\u00f3a t\u00f2a nh\u00e0 BMS.<\/li>\n<\/ul>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-1571170000\">\n\n\t<div id=\"col-1329320485\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h5><span style=\"color: #ff0000;\">\u00a0<strong><span class=\"fontstyle0\">Standard Magnetic Flow\/Energy Meter<\/span><\/strong><\/span><\/h5>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\">Model: <strong>\u00a0<span class=\"fontstyle0\">ALMAGWP (Origin: China)<\/span><\/strong><\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-7294\" src=\"https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/almagwp-flow-meter.jpg\" alt=\"\" width=\"259\" height=\"259\" srcset=\"https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/almagwp-flow-meter.jpg 222w, https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/almagwp-flow-meter-12x12.jpg 12w\" sizes=\"auto, (max-width: 259px) 100vw, 259px\" \/><\/p>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\">\u1ee8ng d\u1ee5ng:<strong> Any conductive fluids<\/strong><\/span><\/p>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\">\u2022 Line Sizes: DN10~DN2000<br \/>\n\u2022 Flow Range (Velocity): 0.3~12 m\/s<br \/>\n\u2022 Accuracy: \u00b10.5% of reading (Velocity \u2265 0.5 m\/s)<br \/>\n\u00b13 mm\/s (Velocity &lt; 0.5 m\/s)<br \/>\n\u2022 Connections: Flanged, wafer, sanitary<br \/>\n\u2022 Outputs: Pulse, 4-20mA, HART, RS485, Relay<br \/>\n\u2022 Power: 110\/220 VAC, 24 VDC<\/span><\/p>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\">Download here: <a href=\"https:\/\/smartmeasurement.com\/wp-content\/uploads\/2020\/06\/ALMAG_WP-20221304.pdf\" target=\"_blank\" rel=\"noopener\">General Purpose Magnetic Flow Meter Catalog<\/a><\/span><\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-809988397\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h5><strong><span style=\"color: #ff0000;\">Insertion electromagnetic flow meter<\/span><\/strong><\/h5>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\">Model:<span style=\"color: #000000;\"> <strong>ALMAG-IS <span class=\"fontstyle0\">(Origin: China)<\/span><\/strong><\/span><\/span><\/p>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-7295\" src=\"https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/ALMAG-IS-insertion-electromagnetic-flow-meter.jpg\" alt=\"\" width=\"185\" height=\"261\" srcset=\"https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/ALMAG-IS-insertion-electromagnetic-flow-meter.jpg 323w, https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/ALMAG-IS-insertion-electromagnetic-flow-meter-9x12.jpg 9w\" sizes=\"auto, (max-width: 185px) 100vw, 185px\" \/><br \/>\n\u1ee8ng d\u1ee5ng: <strong>Water &amp; wastewater, large pipe sizes<\/strong><\/span><\/p>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\">\u2022 Line Sizes: DN50~DN3000<br \/>\n\u2022 Flow Range (Velocity): 0.5~10 m\/s<br \/>\n\u2022 Accuracy: \u00b11.5% of reading (Velocity \u2265 0.6 m\/s)<br \/>\n\u00b19 mm\/s (Velocity &lt; 0.6 m\/s)<br \/>\n\u2022 Connections: Threaded, weld-type, Hot-tap ball valve<br \/>\n\u2022 Outputs: Pulse, 4-20mA, HART, RS485, Relay<br \/>\n\u2022 Power: AC, DC<\/span><\/p>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\">Download here: <a href=\"https:\/\/smartmeasurement.com\/wp-content\/uploads\/2025\/04\/ALMAG-IS_20222109.pdf\" target=\"_blank\" rel=\"noopener\">Insertion Magnetic Flow Meter Catalog<\/a><\/span><\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-1544146376\">\n\n\t<div id=\"col-281338159\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h5 id=\"Graphic_Multi-Channel_Ultrasonic_Portable_Meters\" class=\"elementor-heading-title elementor-size-default uael-toc-text\"><span style=\"color: #ff0000;\"><strong>Graphic Multi-Channel Ultrasonic Portable Meters<\/strong><\/span><\/h5>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\">Model: \u00a0<strong><span class=\"fontstyle0\">ALSONIC DSP (Origin: USA)<\/span><\/strong><\/span><\/p>\n<p><a href=\"https:\/\/smartmeasurement.com\/ultrasonic-flow-meters\/wall-mount-flow-meters\/graphic-multi-channel-permanent\/\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-7276\" src=\"https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/Wall-Mount-Portable-ALSONIC-DSP.jpg\" alt=\"\" width=\"243\" height=\"302\" srcset=\"https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/Wall-Mount-Portable-ALSONIC-DSP.jpg 447w, https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/Wall-Mount-Portable-ALSONIC-DSP-10x12.jpg 10w\" sizes=\"auto, (max-width: 243px) 100vw, 243px\" \/><\/a><\/p>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\">\u1ee8ng d\u1ee5ng: <strong><span class=\"fontstyle0\">Clean or dirty fluids with high accuracy requirements<\/span><\/strong><br \/>\n<\/span><\/p>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\">\u2022 Fluids: liquids w\/ \u2264 30% particulates\/bubbles<br \/>\n\u2022 Line sizes: DN20~DN6000<br \/>\n\u2022 Flow Range (Velocity): 0.02~20m\/s<br \/>\n\u2022 Temperature: -40~+120 \u00b0C<br \/>\n\u2022 Accuracy: std \u00b11.0% of reading<br \/>\nopt \u00b10.5% of reading<br \/>\n\u2022 Transducer: Clamp on<br \/>\n\u2022 Output: Relay, 4-20mA, RS485, graphic display<\/span><\/p>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\">Download here: <a href=\"https:\/\/smartmeasurement.com\/wp-content\/uploads\/2024\/10\/ALSONIC-DSP-241610.pdf\" target=\"_blank\" rel=\"noopener\">Alsonic DSP Portable Ultrasonic Flow Meter Catalog<\/a><\/span><\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-351224700\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h5 id=\"Portable_Ultrasonic_Energy_Flow_Meters\" class=\"elementor-heading-title elementor-size-default uael-toc-text\"><strong><span style=\"color: #ff0000;\">Portable Ultrasonic Energy\u00a0Flow\u00a0Meters<\/span><\/strong><\/h5>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\">Model: <strong><span class=\"fontstyle0\">\u00a0<\/span><\/strong><strong><span class=\"fontstyle0\">ALSONIC FX2 (Origin: USA)<\/span><\/strong><\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-7277\" src=\"https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/Standard-Wall-Mount-ALSONIC-FX2.jpg\" alt=\"\" width=\"416\" height=\"247\" srcset=\"https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/Standard-Wall-Mount-ALSONIC-FX2.jpg 752w, https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/Standard-Wall-Mount-ALSONIC-FX2-18x12.jpg 18w\" sizes=\"auto, (max-width: 416px) 100vw, 416px\" \/><\/p>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\">\u1ee8ng d\u1ee5ng: <strong>Low cost flow and\/or energy\/BTU<\/strong><\/span><\/p>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\">\u2022 Fluids: Clean liquids &lt;1-2% bubble\/particles<br \/>\n\u2022 Line sizes: DN 15~DN1200<br \/>\n\u2022 Flow Velocity: 1~33ft\/s (0.3~10m\/s)<br \/>\n\u2022 Temperature: -20~+110 \u00b0C<br \/>\n\u2022 Accuracy: \u00b11% of reading<br \/>\n\u2022 Transducer: Clamp-on or inline<br \/>\n\u2022 Outputs: 4-20 mA, pulse, RS-485<br \/>\n\u2022 Inputs: PT1000-optional<\/span><\/p>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\">Download here: <a href=\"https:\/\/smartmeasurement.com\/wp-content\/uploads\/2025\/01\/ALSONIC-FX2_VERSION20240708.pdf\" target=\"_blank\" rel=\"noopener\">Alsonic FX2 Ultrasonic Flow Meter Catalog<\/a><\/span><\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-1544596168\">\n\n\t<div id=\"col-1827337158\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h5><span style=\"color: #ff0000;\"><strong><span class=\"fontstyle0\">ALSONIC ULTRASONIC FLOWMETERS<\/span><\/strong><\/span><\/h5>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\">Model: <strong>\u00a0<span class=\"fontstyle0\">Portable ALSONIC PL (Origin: USA)<\/span><\/strong><\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-7278\" src=\"https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/Portable-ALSONIC-PL.jpg\" alt=\"\" width=\"483\" height=\"254\" srcset=\"https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/Portable-ALSONIC-PL.jpg 930w, https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/Portable-ALSONIC-PL-768x404.jpg 768w, https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/Portable-ALSONIC-PL-18x9.jpg 18w\" sizes=\"auto, (max-width: 483px) 100vw, 483px\" \/><\/p>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\">\u1ee8ng d\u1ee5ng: \u00a0<strong><span class=\"fontstyle0\">Portable flow\/energy meter<\/span><\/strong><\/span><\/p>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\">\u2022 Fluids: Clean liquids &lt;1-2% bubble\/particles<br \/>\n\u2022 Line sizes: DN15~DN1200<br \/>\n\u2022 Flow range (Velocity): \u00b10.1~\u00b112m\/s<br \/>\n\u2022 Temperature: -40 ~ + 75 \u00b0C<br \/>\n\u2022\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0-40 ~ + 110 \u00b0C<br \/>\n\u2022 Accuracy: \u00b11% of reading<br \/>\n\u2022 Range: \u00b10.1~\u00b112 m\/s standard;<br \/>\n\u2022 Outputs: 4-20mA, RS485\/Modbus<\/span><\/p>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\">Download here: <a href=\"https:\/\/smartmeasurement.com\/wp-content\/uploads\/2020\/06\/ALSONIC-PL_20212806.pdf\" target=\"_blank\" rel=\"noopener\">Alsonic PL Ultrasonic Flow &amp; Energy Meter Catalog<\/a><\/span><\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-948782190\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h5><span style=\"color: #ff0000;\"><strong><span class=\"fontstyle0\">ALSONIC ULTRASONIC FLOWMETERS<\/span><\/strong><\/span><\/h5>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\">Model: \u00a0<strong><span class=\"fontstyle0\">ALSONIC MINI (Origin: USA)<\/span><\/strong><\/span><\/p>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-7279\" src=\"https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/ALSONIC-MINI.jpg\" alt=\"\" width=\"437\" height=\"243\" srcset=\"https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/ALSONIC-MINI.jpg 584w, https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/ALSONIC-MINI-18x10.jpg 18w\" sizes=\"auto, (max-width: 437px) 100vw, 437px\" \/><br \/>\n\u1ee8ng d\u1ee5ng:<strong> <span class=\"fontstyle0\">DI water, dosing, very low flows<\/span><\/strong><\/span><\/p>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\">\u2022 Fluids: clean liquid &lt;1-2% bubble\/particles<br \/>\n\u2022 Line sizes: DN15~DN40<br \/>\n\u2022 Flow range (Velocity): 0.1 m\/s~5.0 m\/s<br \/>\n\u2022 Temperature: 0~+50 \u00b0C<br \/>\n\u2022 Accuracy: std \u00b12% of reading, opt \u00b11% of reading<br \/>\n\u2022 Transducers: Plug and play; no need for transducer alignment<br \/>\n\u2022 Analog output: 4~20mA, Maximum load: 600\u03a9<br \/>\n\u2022 Alarm output: OCT, Upper and lower limit alarm function (optional)<br \/>\n\u2022 Digital Communication: RS-485\/Modbus<\/span><\/p>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\">Download here:\u00a0<a href=\"https:\/\/smartmeasurement.com\/wp-content\/uploads\/2025\/03\/ALSONIC-MINI-VERSION-20241605.pdf\">Alsonic MINI catalog<\/a><\/span><\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-690147594\">\n\n\t<div id=\"col-1016161925\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h5 id=\"Sewer_Transit_Time_Open_Channel_Flow_Meters\" class=\"wp-block-heading uael-toc-text\"><span style=\"color: #ff0000;\"><strong>Sewer Transit Time Open Channel Flow Meters<\/strong><\/span><\/h5>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\">Model: <strong>\u00a0<span class=\"fontstyle0\">ALSONIC &#8211; SAVM (Origin: USA)<\/span><\/strong><\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-7301\" src=\"https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/ALSONIC-SAVM.jpg\" alt=\"\" width=\"251\" height=\"356\" srcset=\"https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/ALSONIC-SAVM.jpg 307w, https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/ALSONIC-SAVM-8x12.jpg 8w\" sizes=\"auto, (max-width: 251px) 100vw, 251px\" \/><\/p>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\">\u1ee8ng d\u1ee5ng: <strong>\u00a0<span class=\"fontstyle0\">Streams, channels, rivers, sewer systems<\/span><\/strong><\/span><\/p>\n<ul>\n<li>Fluids: Clean and\/or dirty water including waste water<\/li>\n<li>Line sizes: DN150~DN1200 (SAVM), up to 40m (AVM)<\/li>\n<li>Transducers: up to 4-path<\/li>\n<li>Accuracy: std \u00b11.0% of reading<\/li>\n<li>\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 opt \u00b10.5% of reading<\/li>\n<li>Output: Relay, 4-20mA, RS-485\/Modbus<\/li>\n<\/ul>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\">Download here: \u00a0<a href=\"https:\/\/smartmeasurement.com\/wp-content\/uploads\/2025\/06\/ALSONIC-SAVM-VERSION-20250306.pdf\" target=\"_blank\" rel=\"noopener\">ALSONIC-SAVM Open Channel Flow Meter Catalog<\/a><\/span><\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-645755080\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h5 id=\"Microwave_Radar_Open_Channel_Flow_Meters\" class=\"elementor-heading-title elementor-size-default uael-toc-text\"><strong><span style=\"color: #ff0000;\">Microwave Radar Open Channel Flow Meters<\/span><\/strong><\/h5>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\">Model:<strong> ALSONIC-RAVM SC\/MC <span class=\"fontstyle0\"> (Origin: USA)<\/span><\/strong><\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-7309\" src=\"https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/alsonicravm-flowmeter-calcu.jpg\" alt=\"\" width=\"282\" height=\"350\" srcset=\"https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/alsonicravm-flowmeter-calcu.jpg 351w, https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/alsonicravm-flowmeter-calcu-10x12.jpg 10w\" sizes=\"auto, (max-width: 282px) 100vw, 282px\" \/><\/p>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\">\u1ee8ng d\u1ee5ng:<b> <span class=\"fontstyle0\">Non contact open channel for streams, channels, rivers, sewer systems<\/span>\u00a0<\/b><\/span><\/p>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\">\u2022 Fluids: Clean or dirty water\u2022 Flow path: 0.45~15m per transducer<br \/>\n\u2022 Depth: 0-70 meters<br \/>\n\u2022 Transducer: Single or multi(up to 32 points)<br \/>\n\u2022 Output: Relay, RS-485\/Modbus<\/span><\/p>\n<p><span style=\"font-family: Arial, Helvetica, sans-serif;\">Download here: <a href=\"https:\/\/smartmeasurement.com\/wp-content\/uploads\/2025\/05\/ALSONIC-RAVM-SC-VERSION-20250805.pdf\" target=\"_blank\" rel=\"noopener\">ALSONIC-RAVM SC\u00a0 \/\u00a0 <\/a><a href=\"https:\/\/smartmeasurement.com\/wp-content\/uploads\/2025\/05\/ALSONIC-RAVM-MC-VERSION20250805.pdf\" target=\"_blank\" rel=\"noopener\">ALSONIC-RAVM MC<\/a><\/span><\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-334759383\">\n<\/div>\n\n\t<div id=\"col-122908590\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\">\u0110\u1ec3 t\u00ecm hi\u1ec3u th\u00eam th\u00f4ng tin v\u1ec1 c\u00e1c gi\u1ea3i ph\u00e1p b\u01a1m\/van b\u00f9n qu\u1eb7ng c\u1ee7a ch\u00fang t\u00f4i, Qu\u00fd kh\u00e1ch h\u00e0ng vui l\u00f2ng truy c\u1eadp link sau:<\/p>\n<p style=\"text-align: center;\"><a href=\"https:\/\/smartmeasurement.com\/\">https:\/\/smartmeasurement.com\/<\/a><\/p>\n<p style=\"text-align: center;\"><a href=\"https:\/\/smartmeasurement.com\/\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-7273\" src=\"https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/Smart.png\" alt=\"\" width=\"400\" height=\"100\" srcset=\"https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/Smart.png 400w, https:\/\/vintec.com.vn\/wp-content\/uploads\/2026\/03\/Smart-18x5.png 18w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>&nbsp; For further information, please feel free to explore our portal website: https:\/\/smartmeasurement.com\/<\/p>","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-7274","page","type-page","status-publish","hentry"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/vintec.com.vn\/vi\/wp-json\/wp\/v2\/pages\/7274","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vintec.com.vn\/vi\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/vintec.com.vn\/vi\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/vintec.com.vn\/vi\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/vintec.com.vn\/vi\/wp-json\/wp\/v2\/comments?post=7274"}],"version-history":[{"count":39,"href":"https:\/\/vintec.com.vn\/vi\/wp-json\/wp\/v2\/pages\/7274\/revisions"}],"predecessor-version":[{"id":7332,"href":"https:\/\/vintec.com.vn\/vi\/wp-json\/wp\/v2\/pages\/7274\/revisions\/7332"}],"wp:attachment":[{"href":"https:\/\/vintec.com.vn\/vi\/wp-json\/wp\/v2\/media?parent=7274"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}