OXYGEN ANALYSER IN FLUE GASES
With proven efficiency and reliability on a wide range of factory sites for many years, the ATK/F is your most trustable partner for the combustion control. Conventional combustion or waste incineration, the ATK/F can even withstand the harshest conditions.
The ATK range analysers stand out from other systems by their simple design:
• Simple set-up with no need of reference air (MicroPoas®*).
• Easy to use with access to all the functions of the device thanks to a HMI simplified.
• Purposely designed to require only simple and low maintenance
MEASUREMENT PRINCIPLE: MicroPoas®, Zirconia sensor with built-in metallic reference
RANGE: 0.01 to 25% vol. O2
ACCURACY: 0.5% of the measurement
MAXIMUM TEMPERATURE OF THE GASES YOU ANALYSE:
- ATK/F: 316L stainless steel probe tubes – Tmax = 700°C
- ATK/I: Inconel 600 probe tubes – Tmax = 1000°C
- ATK/HR: HR160 probe tubes – Tmax = 1000°C and corrosive flue gases
- ATK/HC: Hastelloy C2000 probe tubes – Tmax = 600°C and corrosive flue gases
- ATK/C: Ceramic probe tubes – Tmax = 1300°C
- ATK/CS: Silicon carbide outer probe tube – Tmax = 1300°C
- ATK/EK: Kanthal probe tubes – Tmax =1300°C
- ATK/T: Halar coated probe tubes -Tmax = 150°C
PERFORMANCES
- Combustion and incineration control
- Integrated MicroPoas® technology
- Continuous performance maintained up to 1300°C, depending on the model
- Semi in situ analysis
- User-friendly, fast setting
- Low maintenance and servicing requirements
- Extremely high reliability
APPLICATIONS
- Combustion control in power generation (Economizer, after preheat – APH, CEMS)
- Heating operation
- Industrial and household waste incineration
- VOC (Volatile Organic Compounds) incineration
- Industrial kilns