OXYGEN ANALYSER IN FLUE GASES

With proven efficiency and reliability on a wide range of factory sites for many years, the ATK/F is your most trustable partner for the combustion control. Conventional combustion or waste incineration, the ATK/F can even withstand the harshest conditions.

 

 

The ATK range analysers stand out from other systems by their simple design:
• Simple set-up with no need of reference air (MicroPoas®*).
• Easy to use with access to all the functions of the device thanks to a HMI simplified.
• Purposely designed to require only simple and low maintenance

MEASUREMENT PRINCIPLE: MicroPoas®, Zirconia sensor with built-in metallic reference 

RANGE: 0.01 to 25% vol. O2

ACCURACY: 0.5% of the measurement  

MAXIMUM TEMPERATURE OF THE GASES YOU ANALYSE:

  • ATK/F: 316L stainless steel probe tubes – Tmax = 700°C
  • ATK/I: Inconel 600 probe tubes – Tmax = 1000°C
  • ATK/HR: HR160 probe tubes – Tmax = 1000°C and corrosive flue gases
  • ATK/HC: Hastelloy C2000 probe tubes – Tmax = 600°C and corrosive flue gases
  • ATK/C: Ceramic probe tubes – Tmax = 1300°C
  • ATK/CS: Silicon carbide outer probe tube – Tmax = 1300°C
  • ATK/EK: Kanthal probe tubes – Tmax =1300°C
  • ATK/T: Halar coated probe tubes -Tmax = 150°C

PERFORMANCES

  • Combustion and incineration control
  • Integrated MicroPoas® technology
  • Continuous performance maintained up to 1300°C, depending on the model 
  • Semi in situ analysis
  • User-friendly, fast setting
  • Low maintenance and servicing requirements
  • Extremely high reliability

APPLICATIONS

  • Combustion control in power generation (Economizer, after preheat – APH, CEMS)
  • Heating operation
  • Industrial and household waste incineration
  • VOC (Volatile Organic Compounds) incineration
  • Industrial kilns