Solution Water & Wastewater

Vintec has been providing advanced process instrumentation for the stable supply of clean water, wastewater treatment for protecting the water environment, water loss management and optimization of plant operation for reducing running costs.

Applications
  • Wastewater Treatment Plants
  • Regeneration of Water Wells
  • Water Abstraction Control
  • Water Distribution Networks
  • Drinking Water
  • Pressure Filter System in Water Treatment Plants
  • Booster Pump Works with Collector Well in Water Treatment Facilities
  • Corrosion Protection and Disinfection
  • Clean Water From Water Treatment Facilities
  • Open Channel Measurement in Partially Filled Wastewater and Sludge Purification Plants
  • Open Channel Measurement in Partially Filled Water Distribution Channels
  • Untreated Wastewater
  • Measurement of Iron Chloride in Light Load Aeration
  • Flow Measurement of Sludge
  • Methanol Measurement with Coriolis Flowmeters
  • Aeration Process
  • Biogas Measurement
  • Biogas for Cogeneration Plants in Wastewater Facilities
  • Biogas from Landfills for Cogeneration
Magnetic flowmeters

ALMAG Series

  • Smart Measurement’s offers a complete line of magnetic flow meters suitable for use in the water and wastewater industries. From ALMAG-WP for general-purpose applications; No power or only solar power are available, the battery powered ALMAG-BAT is available; For large pipe sizes, the insertion style ALMAG-IS can accommodate pipe sizes of up to 120” (3000 mm); ALMAG-EG which is frequently used for BTU/energy flow measurement required in building automation application
Turbine flowmeters

ALTM Series

  • Smart Measurement’s ALTM turbine flow meter comes in sizes ranging from ½” to 12” (15-300 mm) and features a wide turn-down ratio with minimum uncertainty and a very repeatable output.  The ALTM is excellent for precise measurement of instantaneous flows of low-viscosity fluids such as tap and demineralized water, fuels, liquefied gasses, light fuel oils, solvents, and pharmaceutical fluids.
 Ultrasonic flowmeters

ALSONIC Series

  • ALSONIC series employ both transit time and Doppler ultrasonic flow measurement techniques to allow for non-invasive clamp-on and inline installation in liquid flow measurement applications.
Open Channel flowmeters

ALSONIC Series

  • Accurate flow measurement in open channels, vital for water management in wastewater treatment, stormwater monitoring, and irrigation systems.
Portable Clamp-On flowmeters

ALSONIC Series

  • Portable clamp-on ultrasonic transit time flowmeters shine in environmental monitoring and field diagnostics, where temporary and detailed analysis of fluid flow is required. Their portability, coupled with advanced data logging capabilities, allows for comprehensive assessment and troubleshooting in challenging fluid dynamics scenarios.
Water and Energy Ultrasonic flowmeters

ALSONIC Series

  • Reflecting the shift towards more efficient and sustainable technologies, our selection of ultrasonic flow meters for municipal/residential water flow and BTU/energy measurement is expanding. As these ultrasonic solutions become more cost-effective, they are increasingly replacing traditional mechanical water meters, offering superior efficiency and a maintenance-free experience.
 Standard Magnetic Flow/Energy Meter

Model:  ALMAGWP (Origin: China)

Applications: Any conductive fluids

• Line Sizes: DN10~DN2000
• Flow Range (Velocity): 0.3~12 m/s
• Accuracy: ±0.5% of reading (Velocity ≥ 0.5 m/s)
±3 mm/s (Velocity < 0.5 m/s)
• Connections: Flanged, wafer, sanitary
• Outputs: Pulse, 4-20mA, HART, RS485, Relay
• Power: 110/220 VAC, 24 VDC

Download here: General Purpose Magnetic Flow Meter Catalog

Insertion electromagnetic flow meter

Model: ALMAG-IS (Origin: China)


Applications: Water & wastewater, large pipe sizes

• Line Sizes: DN50~DN3000
• Flow Range (Velocity): 0.5~10 m/s
• Accuracy: ±1.5% of reading (Velocity ≥ 0.6 m/s)
±9 mm/s (Velocity < 0.6 m/s)
• Connections: Threaded, weld-type, Hot-tap ball valve
• Outputs: Pulse, 4-20mA, HART, RS485, Relay
• Power: AC, DC

Download here: Insertion Magnetic Flow Meter Catalog

Graphic Multi-Channel Ultrasonic Portable Meters

Model:  ALSONIC DSP (Origin: USA)

Application: Clean or dirty fluids with high accuracy requirements

• Fluids: liquids w/ ≤ 30% particulates/bubbles
• Line sizes: DN20~DN6000
• Flow Range (Velocity): 0.02~20m/s
• Temperature: -40~+120 °C
• Accuracy: std ±1.0% of reading
opt ±0.5% of reading
• Transducer: Clamp on
• Output: Relay, 4-20mA, RS485, graphic display

Download here: Alsonic DSP Portable Ultrasonic Flow Meter Catalog

Portable Ultrasonic Energy Flow Meters

Model:  ALSONIC FX2 (Origin: USA)

Application: Low cost flow and/or energy/BTU

• Fluids: Clean liquids <1-2% bubble/particles
• Line sizes: DN 15~DN1200
• Flow Velocity: 1~33ft/s (0.3~10m/s)
• Temperature: -20~+110 °C
• Accuracy: ±1% of reading
• Transducer: Clamp-on or inline
• Outputs: 4-20 mA, pulse, RS-485
• Inputs: PT1000-optional

Download here: Alsonic FX2 Ultrasonic Flow Meter Catalog

ALSONIC ULTRASONIC FLOWMETERS

Model:  Portable ALSONIC PL (Origin: USA)

Applications:  Portable flow/energy meter

• Fluids: Clean liquids <1-2% bubble/particles
• Line sizes: DN15~DN1200
• Flow range (Velocity): ±0.1~±12m/s
• Temperature: -40 ~ + 75 °C
•                       -40 ~ + 110 °C
• Accuracy: ±1% of reading
• Range: ±0.1~±12 m/s standard;
• Outputs: 4-20mA, RS485/Modbus

Download here: Alsonic PL Ultrasonic Flow & Energy Meter Catalog

ALSONIC ULTRASONIC FLOWMETERS

Model:  ALSONIC MINI (Origin: USA)


Applications: DI water, dosing, very low flows

• Fluids: clean liquid <1-2% bubble/particles
• Line sizes: DN15~DN40
• Flow range (Velocity): 0.1 m/s~5.0 m/s
• Temperature: 0~+50 °C
• Accuracy: std ±2% of reading, opt ±1% of reading
• Transducers: Plug and play; no need for transducer alignment
• Analog output: 4~20mA, Maximum load: 600Ω
• Alarm output: OCT, Upper and lower limit alarm function (optional)
• Digital Communication: RS-485/Modbus

Download here: Alsonic MINI catalog

Sewer Transit Time Open Channel Flow Meters

Model:  ALSONIC – SAVM (Origin: USA)

Applications:  Streams, channels, rivers, sewer systems

  • Fluids: Clean and/or dirty water including waste water
  • Line sizes: DN150~DN1200 (SAVM), up to 40m (AVM)
  • Transducers: up to 4-path
  • Accuracy: std ±1.0% of reading
  •                 opt ±0.5% of reading
  • Output: Relay, 4-20mA, RS-485/Modbus

Download here:  ALSONIC-SAVM Open Channel Flow Meter Catalog

Microwave Radar Open Channel Flow Meters

Model: ALSONIC-RAVM SC/MC (Origin: USA)

Applications: Non contact open channel for streams, channels, rivers, sewer systems 

• Fluids: Clean or dirty water• Flow path: 0.45~15m per transducer
• Depth: 0-70 meters
• Transducer: Single or multi(up to 32 points)
• Output: Relay, RS-485/Modbus

Download here: ALSONIC-RAVM SC  /  ALSONIC-RAVM MC

 

For further information, please feel free to explore our portal website:

https://smartmeasurement.com/